Globally recognised provider of proficiency tests, running over 400 tests annually across an extensive range of matrices and analytes
A single sample taken by an ecologist at any time during the newt breeding season can determine their presence or absence, saving you time and money
As well as accredited analyses for a range of matrices from food producing animals. Fera also provide bespoke method development solutions and un-accredited analyses for other analyte/matrix combinations. Processed meat and samples high in fat may present an analytical challenge and require additional method development prior to analysis and as such cannot always be analysed using accredited methodology. Please get in touch using the contact details on this page to confirm testing requirements and accreditation status if unsure.
Fera’s ISO 17025 accreditation status can be found at https://www.ukas.com/download-schedule/1642/Testing/.
Fera food safety experts make use of innovative testing methods to highlight the levels of tiamulin, within your food samples. We can also provide the evidence required by regulators to verify that the levels of tiamulin within your food products are compliant.
Tiamulin is a member of the pleuromutilin class of antibiotic drugs that is used in the treatment of bacterial infections particularly for pigs and poultry e.g swine dysentery.
Regulatory limits strictly control its use, with Maximum Residue Limits (MRL) being defined in Commission Regulation (EU) 37/2010 (or as amended) for a range of food producing species. MRLs have been set in muscle, skin / fat, liver and eggs. The defined marker residue for tiamulin in eggs is defined as parent tiamulin, whereas its major metabolite 8-α-hydroxymutilin, is the marker residue in other tissues.
The analytical methods used at Fera are based on liquid chromatography–tandem mass spectrometry (LC–MS/MS). The methods have been validated in accordance with the principles set out in Commission Decision 2002/657/EC, for the majority of analyte / matrix combinations.
Our analysis is accredited to ISO17025 by the United Kingdom Accreditation Service (UKAS).
Confirmatory analysis, where required, will be at the same value as the analysis performed. Fera will contact you beforehand to establish if the additional analysis is required. The delivery time for confirmatory results will be 10 working days from your instruction to proceed.
Detail | Specification |
---|---|
Standard Turnaround Time | 10 working days |
Method Used | LC-MS/MS |
Accreditation | ISO 17025 |
Please review your sample(s). Additional sample charges may apply where applicable.
There are no samples associated with this product at this time
Copyright © 2024 Fera Science Limited (“Fera”). All rights reserved.