Esters of 3-MCPD and 2-MCPD & Glycidyl Esters

Test Code
EC00014
£446.00
Standard Price per sample £446.00
up to 1

Additional charge of £7 will be added per analyte after initial 4 selection.

Esters of 3-MCPD and 2-MCPD  & Glycidyl Esters
  • Method Used
    GC-MS
  • LOD (limit of detection)
    5 µg/kg
    10 µg/kg
  • Accreditation
    Only free 3-MCPD method
  • Standard Turnaround Time
    20 working days

Feras contamination scientists are able to offer a range of MCPD test variants upon request. Please contact us to learn more.

3-MCPD (3-monochloropropane-1,2-diol), 2-MCPD (2-monochloropropane-1,2-diol) and glycidyl esters are a by-product of processing or refining edible oils and fats and are only relatively recent in their discovery. 3-MCPD and 2-MCPD are food processing contaminants formed by heat as a reaction product of triacyl glycerols, phospholipids or glycerol and hydrochloric acid in fat-based or fat-containing foods. Depending on the type of food it may occur as a free substance, in the form of an ester with fatty acids or in both forms. Glycidyl esters (GE) are compounds formed usually when refining vegetable oils at high temperatures, approx. 200°C. They may occur in margarines and vegetable oils, but also in low levels in bread, biscuits and malt based food ingredients.

With various health implications associated with 3-MCPD, 2-MCPD and their esters there is a real need to control their levels within foods. Palm oil is naturally prone to higher levels of 2 and 3-MCPD esters due to the high levels of diglycerides. These high levels can be even larger through rapid soy protein hydrolyzation. With the wide range of uses associated with palm oil, including baby food and mayonnaise, as well as bakery products, the need for accurate testing is paramount. 2 and 3-MCPD esters and glycidyl esters occur in a variety of foods, most notably meats, infant formulae, and milk powders.

 

The regulation & recent studies from ESFA on Glycerol based process contaminants (MCPD and GE)

3-MCPD is a possible human carcinogen for which the Scientific Committee on Food has established a tolerable daily intake (TDI) of 2 µg/kg body weight. As such it is recommended to reduce the levels of 3-MCPD, 2-MCPD and their esters as much as possible. Scientific evidence has shown that 3-MCPD is released from 3-MCPD esters by regular digestion in the human digestive tract and therefore are considered to have the same toxicological profile as 3-MCPD (European food legislation - Commission Regulation EC 1881/2006). For soy sauce and hydrolysed vegetable protein the European Commission set a maximum level of 20µg/kg. Recent studies by ESFA found the amount of 3-MCPD in the form of fatty acid esters in edible oils and fats ranged from around 500 to around 10.000µg/kg.

With UKAS accredited testing for 3-MCPD, 1,32-DCP and acrylamide, and the ability to carry out 2 and 3-MCPD esters and glycidyl esters analysis, Fera is at the forefront of Food Process Contaminant testing.

Please contact us to discuss volume discounts.

Analytes

Search for Specific Analytes

        Detail Specification

        Standard Turnaround Time

        20 working days

        Method Used

        GC-MS

        LOD (limit of detection)

        • 5 µg/kg
        • 10 µg/kg

        Accreditation

        Only free 3-MCPD method

        Department

        Food Safety

        You may also be interested in

        Polycyclic Aromatic Hydrocarbon (PAH) Testing

        Fera food contaminant experts are able to highlight the levels of a range of PAHs within your food sample as part of this accredited analysis activity. Through our industry accepted methods and leading technologies we are able to provide accurate analysis within a timely turnaround window. We are also able to work closely with you to perform tailored analysis of your samples on request.

        Many different matrices can be tested not just foods, contact us for further information or to discuss your needs with one of our scientists.

        Dioxins and Polychlorinated biphenyls (PCBs)

        Fera food safety experts are able to establish the levels of a range of Dioxins and PCBs within your food sample as part of a complete overview of the safety of your foodstuffs. Our accredited methods of analysis are important to confirm that levels of these potentially harmful chemicals within your foodstuffs are below legislative limits thus avoiding potentially damaging product recalls, refusals, and loss of customer trust. With this analysis, our food safety experts can measure the levels of both dioxin like and non-dioxin like PCBs in your food samples.

        Many different matrices can be tested not just foods, contact us for further information or to discuss your needs with one of our scientists.

        Metals Analysis

        Fera food testing experts perform extensive mineral and trace element testing of food samples, accredited to ISO17025, to provide insights into the quality and safety of your foodstuffs.

        Esters of 3-MCPD and 2-MCPD & Glycidyl Esters

        Subtotal £446.00

        Add Samples

        0 / 1
        i
        This denotes the current samples you have selected in orange against the samples that are already included within the base price.

        Your Current Samples

        Please review your sample(s). Additional sample charges may apply where applicable.

        There are no samples associated with this product at this time

        0

        Choose Your Analytes

        Please select at least one analyte.

        Copyright © 2024 Fera Science Limited (“Fera”). All rights reserved.

        Registered Office: York BioTech Campus, Sand Hutton, York, YO41 1LZ. Registered in England & Wales, No 9413107. VAT Registration ID: GB 456401013
        For further information about how Fera uses any personal data collected from you, please see our Privacy Notice at www.fera.co.uk/privacy-policy.